casting iron materialÂ
Multi-jet Dry Type Vane Wheel Water Meter
It is a multi-jet super dry water meter for residentialÂ
application in sizes 15mm-20mm for cold  and hot meter.
Features
Compact design with smaller meter body.
Brass body is only 570g weight for save cost
45° inclined register, hot wire tamper proof.
Magnetic drive mechanism with anti-magnetic protection.
External regulation device
Standards ComplianceÂ
Directive 2004/22/EC on measuring instruments;Â
the European  Standard EN14154+A1+A2: Water Meter;Â
the International  Organization of Legal Metrology OIML R-49: 2006(E)
Optional FeaturesÂ
Several lengths and connections available on request
Non return Valve
Reed switch option
Working Conditions
Water temperature: ≤50ºC for cold water meter Â
                   ≤90ºC for  hot water meterÂ
Water pressure:   ≤1MPa or 1.6MPa optional
          (10bar or 16bar option)
Accessories
Each meter has one set coupling optional: 2pcs coupling, 2pcs coupling nuts and 2pcs washers.
Installation requirements
The meter should be installed in horizontal position with the direction of the flow asÂ
indicated by the arrow cast in the meter body with the register face upwards.
Pipeline must be flushed before installation.
The meter should be constantly full of water during operation.
Maximum Permissible Error
In the lower zone from Qmin inclusive up to but excluding Qt is ±5%.
In the upper zone from Qt inclusive up to and including Qs is: cold water meter ±2%.
DN(mm) | Â | 15 | 20 |
Size(inch) | Â | 1/2" | 3/4" |
Q4(m³/h) |  | 3.125 | 5 |
Q3(m³/h) |  | 2.5 | 4 |
R80 | Q2(l/h) | 50 | 80 |
 | Q1(l/h) | 31.25 | 50 |
R100 | Q2(l/h) | 40 | 64 |
 | Q1(l/h) | 25 | 40 |
Max.Reading (m³) | 9999 | ||
Min.Reading (Liter) | 005 | ||
Max.Pressure (bar) | 16 | ||
Pressure Loss (ΔP) | 63 | ||
Max.Temperature | T30 or T90 |
Â
Fixed tube heat exchanger consists of tube bundle, tube plate, shell, head, folded plate, etc. Tube bundle ends fixed in the tube plate, the tube can be expanded (the inner hole of the tube with mechanical expansion, so that the tube wall from the inward to outward extrusion and fixed in the tube plate) or welded to the tube plate. The tube bundle is placed within the tube shell, with headers and flanges fixed at both ends. In this way, one fluid flows from the inside of the tube and the other from the outside. The space between the two heads and the tube plate is used to distribute or collect the fluids inside the tube. The two fluids do not mix with each other, but only exchange heat through the tube wall.
Advantages: simple and compact structure, high pressure resistance, low cost and easy to clean the tube side.
Disadvantages: Risk of blockage when the tube is damaged or needs to be replaced.
When the difference between the wall temperature of the tube bundle and the shell or the coefficient of linear expansion of the material is large, a large thermal stress will be generated in the shell and the tube bundle. A flexible compensation ring (also called expansion joint) should be installed on the shell to reduce the thermal stress.