Model NO.: QS
Position of Pump Shaft: Horizontal Pump
Pump Casing Combined: Horizontal Split Pumps
Mounting Height: Since Irrigation Centrifugal Pumps
Impeller: Closed
Usage: Pump
Item: Split Case Irrigation Pump
Power: Electric, 22 - 3450 Kw
Shaft Seal Type: Gland Seal and Mechanical Seal
Liquid Temperature: Max 125°c
Pump Capacity: 110 - 14400 M3/ Hr
Pump Head: 8 - 140 M
Trademark: An pump
Transport Package: Standard Wooden Case
Specification: ISO, SGS, CE. TUV. BV
Origin: Hebei, China
HS Code: 841370
                                                              High Efficiency Centrifugal Split Case Pump

                                                                                                                
High Efficiency Centrifugal Split Case Pump
                            
 
Model QS pump is a single-stage double-suction horizontal split centrifugal pump and used to transport pure water and the liquid of both physical and chemical nature similar to those of water, the maximum temperature of which must not be over 125 , suitable for water supply and drainage in factories, mines, cities and electric stations, waterlogged land drainage and irrigation of farming land and carious hydraulic projects. This series pump comply with the standards of GB/T3 216 and GB/T5657.

Structure  of Split Case Irrigation Pump. Centrifugal Water Pump
                                                                     
Both inlet and outlet of this pump are placed under the axial line, horizontally and vertical to the axial line, the pump casing is opened in the middle, so it is unneccessary to remove the water inlet and outlet pipelines and motor(or other prime movers). The pump moves CW viewing from the clutch to it. The pump moving CCW can also be made.
 
The main parts of the pump are: pump casing, pump cover , impeller , shaft, dual-suction seal ring, muff, bearing etc.
 
The impeller is static-balance calibrated, fixed with the muff and the muff nuts in both sides and its axial position can be adjusted via the nuts and axial force gets balanced by means of the symmetrical arrangement of its blades.
 
The pump shaft is supported by two single-column centripetal ball bearings, which are mounted inside of the bearing body on both ends of the pump and lubricated with grease. The dual-suction seal ring is used to reduce the leak at the impeller
 
The flexible couplings connect the pump with the motor directly. For pumps driven by belt, there must be an intermediate bracket fitted for supporting the belt pulley.

 Parameters of Split Case Irrigation Pump. Centrifugal Water Pump                                                                               

Model

Flow rate
(m3/hr)

Head
(m)

Speed
(rpm)

Power
(kw)

Eff
(%)

QS150

110~220

35~84

2900

30~55

67~80

QS200

160~351

31~100

2900

37~110

67~85

QS250

324~612

8.6~71

1450

22~132

72~86

QS300

504~972

8~98

1450

30~300

70~84

QS350

745~1663

10~140

1450

55~680

70~88

QS400

900~1620

32~98

980~1480

155~500

71.5~84

QS500

1150~2450

10.6~108

740~970

110~800

70~89

QS600

2304~4000

13~80

730~970

185~900

70~91

QS700

2111~4896

39.5~99.5

740~980

560~1250

72~92

QS800

3960~7200

23.5~84

600~740

450~1600

77~92

QS1000

6000~9900

32~52

600~990

1250

79~87

QS1200

5832~14400

6~95.7

500~745

710~3450

80~90



QA&QC
Reliable and comprehensive quality assurance system ensures the excellent quality of our products. We have got the "International Standard" certification, manufactured according to GB, Department of superscript, and industry standards, we implement a comprehensive quality management during the entire process of production, accordance with the process file processing strictly, and a variety of detection methods etc.


We have meet the requirements of GB3216-89 national Class B accuracy, <>, computer test data monitoring of water test pumping station application. There are physical chemistry laboratory, metallographic analysis room in our factory, for testing material properties in different respects.


1. Quality Policy
   Advocates quality is the life of enterprise, assiduous, the pursuit of excellence
2. Quality objectives
   qualified products rate 99%, factory qualified pass rate: 100%
3. Quality Commitment
  1) We will continue to improve the awareness of quality, implementing as GB/T19001-2000 quality assurance model standard, meeting technical requirements stipulated in the contract. We are not only discharge for the supplier host, but also for the quality of spare parts, external assistance products etc.
  2) We promise the delivery time stipulated in the contract.

Application :

High Efficiency Centrifugal Split Case Pump

Packing and shipping:

High Efficiency Centrifugal Split Case Pump

Copany Information:
High Efficiency Centrifugal Split Case Pump


Contact Us

Helen  Mobile :86-18032481573
Shijiazhuang An Pump Machinery Co.,Ltd
www.angroupcn.com
Tel:86-311-89940549   Fax:86-311-86271170
Anything thing need help, please call me any time, i will try best to help you

High Efficiency Centrifugal Split Case Pump






 

RoHS UL Free samples pvc wire harness end cap

RoHS UL Free samples pvc wire harness end cap



large size steel pipe end cap, insulated pipe end cap (1)
Any  customized dimension & color would be welcome!
Application:                                                                                          
RoHS UL Free samples pvc wire harness end cap  is manufactured by the workmanship of Dip Molding to protect the end of cable, metal tube, rod, nut, and dustproof as well.
 
Features:                                                                                                  
a) Material: Vinyl/Soft PVC
b) Flexible & Durable - Won't Split, Tear or Shred
c) Dust Proof, Fire Resistant, UV Resistant,Environmentally Friendly
d) Printable Surface for private labelling
e) Certificate: REACH, RoHS, UL
 
Property:                                                                                        
 
  Item                                                                                          Test Standard                                                      Test Method                               Result
Appearance                                                                      Clean, Smooth, Transparent, No Bubble                            Visual Inspection                               PASS

Aging Test                                                            168Hrs@136°C without aging                                Aging Box                               PASS
Insulation Resistance                                               DC 500V, Insulation Resistance R≥200MΩ             Insulation Tesistance Tester             PASS
Dielectric Withstand Voltage Test                            AC 2500V/Min (5mA)  No  Breakdown                   Dielectric Withstand Voltage Tester     PASS
Corrosion Resistance                                                Company standard: Q/HT-2004                               Corrosion Device                            PASS
Flammability                                                                            Standard UL 94 V-0                                            Flame Burning                         PASS
      
Internal poly bag and external carton. Special packaging could be customized.

Shipping:

wire harness use heat shrink end caps heat shrink end cap 200mm                                                                                                 
            
Any shipping method is available including courier & forwarder.

Harnessing End Caps

Heat Shrink Wire Caps,Heat Shrink Caps,Elastic Sealing Cap,Heat Shrink End Caps

KEYUACE Materials Co., Ltd. , https://www.insulationtubing.com