Model NO.: NSH-300
Noise Level: Low
Application Fields: Industrial
Certification: RoHS, ISO, CTI
Condition: New
Nominal Flow: 300 M3/H
Motor: 11.0*3kw
Net Weight: 8580kg
Running Weight: 16370kg
Fan Diameter: 3200mm
Water Pressure: 44kpa
Usage: for Manufacture
Trademark: NEWIN
Transport Package: 20/40/40hq Container with Loose Packing
Specification: 1400*3500*4200mm
Origin: China
HS Code: 8419500090
Model NO.: NSH-300
Noise Level: Low
Application Fields: Industrial
Certification: RoHS, ISO, CTI
Condition: New
Nominal Flow: 300 M3/H
Motor: 11.0*3kw
Net Weight: 8580kg
Running Weight: 16370kg
Fan Diameter: 3200mm
Water Pressure: 44kpa
Usage: for Manufacture
Trademark: NEWIN
Transport Package: 20/40/40hq Container with Loose Packing
Specification: 1400*3500*4200mm
Origin: China
HS Code: 8419500090
NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

High Efficiency and Energy Saving
 Newin NSH series cooling tower using excellent quality PVC film as thermal interface material, corrosion resistant, no deformation, curved and diagonal design film effectively prolongs exchange time between high temperature water and air inside cooling tower, which makes air flow smoothly and resistance lower, meanwhile, making the water drift ratio lowest, furthermore, the axial and arc fan, specially designed basin with evenly distributed waterstoma, which highly improved heat exchange rate of cooling tower and lower the entire cooling tower's energy consumption and noise.

Excellent Design and Long lifetime
The shell of cooling tower adopts high quality and toughness glass fiber, beautiful shape, resistants to natural factors and chemical material erosion, looks brand new even after long time use. All the steel shelves are processed by immersive hot galvanized zinc and comply with British BSEN ISO1461:1999 standard, reducing the oxidation mostly, prolong the service life.

 Easy Installation, Reasonable and Practical Usage
 Newin NSH series counter flow square type cooling towers can be paralleled for multi-units, flexible combination, widely used. The body structure is tidy, standardized, compact and strong, which is easy for installation. The design and manufacture are all on basis of practical uses, so it can meet customers' requirement better with high quality.

Components Instruction

Infill
Specially designed S shape PVC infill is vacuum formed of 0.3 thickness or more thicker PVC film with excellent chemical and high distortion resistance, big coefficient of heat transfer, small wind resistance, high ventilation performance. We have different materials like PVC, UPVC, and PP  to suit different water temperature. 
Drift Eliminator
The NSH series cooling tower used easy installed PVC material drift eliminator to prevent water from splashing out of the cooling tower.  
Air Inlet Louver
The air inlet louver is used of F.R.P parts which makes the long life of the whole cooling tower. For sewage water cooling tower, we will use different type of the air inlet louver to meet customers' requirements.
Distribution Nozzles
The distribution nozzles used high quality A.B.S / PP material, easy to installed on the water pipe and make sure the water splashed evenly on the infill.
Steel Structure 
Hop-dip galvanized steel framework to keep the cooling tower great performance and long lifespan, good anti-corrosion, guarantee the use of more than 15 years. Stainless steel hardware parts are also available for options if somewhere special condition needed.  
Sea Water Solution 
Newin cooling tower also provide special solution for sea water application which is suite for sea side industrial project will use sea water as cooling media. Please contact your related sales manager for more details.  

Square Counterflow FRP Cooling Tower for Power Plant 300 Ton

 
                  Item Nominal 
Flow 
(m3/h)
Water
  Pressure   
  (× 104  Pa)
Exhuast  Fan Weight  (T) Overall  Dimension               
          (mm)
DB  (A)
  Model Diameter 
(mm)
Motor   
(Kw× sets)
Net 
weight
Run.  
Weight
L W H
NST-80H/S 80 4 1500 3.0× 1 0.95 1.95 2000 2000 4000 60.0 
NST-100H/S 100 4 1800 4.0× 1 1.05 2.10  2250 2250 4000 60.0 
NST-125H/S 125 4 2100 4.0× 1 1.25 2.32  2500 2500 4000 61.0 
NST-150H/S 150 4 2100 5.5× 1 1.42 2.77  2750 2750 4000 62.0 
NST-175H/S 175 4.2 2400 5.5× 1 1.6 3.25  3000 3000 4200 62.0 
NST-200H/S 200 4.2 2400 7.5× 1 1.75 3.40  3250 3250 4200 62.5 
NST-250H/S 250 4.2 2400 7.5× 1 2.15 4.25  3500 3500 4200 63.0 
NST-300H/S 300 4.4 3200 11.0× 1 2.62 5.10  3750 3750 4400 63.5 
NST-350H/S 350 4.4 3200 11.0× 1 2.95 5.75  4000 4000 4400 64.0 
NST-400H/S 400 4.4 3400 15.0× 1 3.52 7.05  4500 4500 4400 64.5 
NST-160H/D 160 4 1500 3.0× 2 1.86 3.82  4000 2000 4000 62.0 
NST-200H/D 200 4 1800 4.0× 2 2.05 4.11  4500 2250 4000 62.0 
NST-250H/D 250 4 2100 4.0× 2 2.45 4.54  5000 2500 4000 63.0 
NST-300H/D 300 4 2100 5.5× 2 2.78 5.42  5500 2750 4000 64.5 
NST-350H/D 350 4.2 2400 5.5× 2 3.13 6.37  6000 3000 4200 64.5 
NST-400H/D 400 4.2 2400 7.5× 2 3.43 6.66  6500 3250 4200 65.0 
NST-500H/D 500 4.2 2400 7.5× 2 4.21 8.33  7000 3500 4200 65.0 
NST-600H/D 600 4.4 3200 11.0× 2 5.13 9.99  7500 3750 4400 66.5 
NST-700H/D 700 4.4 3200 11.0× 2 5.78 11.27  8000 4000 4400 66.0 
NST-800H/D 800 4.4 3400 15.0× 2 6.89 13.81  9000 4500 4400 66.5 
NST-240H/T 240 4 1500 3.0× 3 2.76 5.67 6000 2000 4000 63.0 
NST-300H/T 300 4 1800 4.0× 3 3.05 6.11  6750 2250 4000 63.0 
NST-375H/T 375 4 2100 4.0× 3 3.63 6.75  7500 2500 4000 64.0 
NST-450H/T 450 4 2100 5.5× 3 4.13 8.06  8250 2750 4000 65.5 
NST-525H/T 525 4.2 2400 5.5× 3 4.65 9.45  9000 3000 4200 65.5 
NST-600H/T 600 4.2 2400 7.5× 3 5.09 9.89  9750 3250 4200 66.5 
NST-750H/T 750 4.2 2400 7.5× 3 6.25 12.36  10500 3500 4200 66.5 
NST-900H/T 900 4.4 3200 11.0× 3 7.62 14.84  11250 3750 4400 67.0 
NST-1050H/T 1050 4.4 3200 11.0× 3 8.58 16.37  12000 4000 4400 67.5 
NST-1200H/T 1200 4.4 3400 15.0× 3 10.24 20.51  13500 4500 4400 68.0 
NST-320H/M 320 4 1500 3.0× 4 3.61 7.41  8000 2000 4000 64.5 
NST-400H/M 400 4 1800 4.0× 4 3.99 7.98  9000 2250 4000 64.5 
NST-500H/M 500 4 2100 4.0× 4 4.75 8.81  10000 2500 4000 65.5 
NST-600H/M 600 4 2100 5.5× 4 5.39 10.52  11000 2750 4000 67.0 
NST-700H/M 700 4.2 2400 5.5× 4 6.08 12.35  12000 3000 4200 67.0 
NST-800H/M 800 4.2 2400 7.5× 4 6.65 12.92  13000 3250 4200 68.0 
NST-1000H/M 1000 4.2 2400 7.5× 4 8.17 16.15  14000 3500 4200 68.0 
NST-1200H/M 1200 4.2 3200 11.0× 4 9.95 19.38  15000 3750 4400 68.5 
NST-1400H/M 1400 4.4 3200 11.0× 4 11.21 21.85  16000 4000 4400 69.0 
NST-1600H/M 1600 4.4 3400 15.0× 4 13.37 26.79  18000 4500 4400 69.5 
Square Counterflow FRP Cooling Tower for Power Plant 300 Ton
Jo.h Zhu
Sales Manager 
  

Shenzhen Newin Machinery c.,Ltd. 
Office Add: No.2H065, Trade Plaza No.5, China South City, Pinghu Street, Longgang Distact, Shenzhen, Guangdong Province, China. 
Factory Add: 1st Yangwu industrial Park, Houda Road, Dalingshan Town, Dongguan City, Guangdong Province, China 
Website: www.newincoolingtower.com
  NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

High Efficiency and Energy Saving
 Newin NSH series cooling tower using excellent quality PVC film as thermal interface material, corrosion resistant, no deformation, curved and diagonal design film effectively prolongs exchange time between high temperature water and air inside cooling tower, which makes air flow smoothly and resistance lower, meanwhile, making the water drift ratio lowest, furthermore, the axial and arc fan, specially designed basin with evenly distributed waterstoma, which highly improved heat exchange rate of cooling tower and lower the entire cooling tower's energy consumption and noise.

Excellent Design and Long lifetime
The shell of cooling tower adopts high quality and toughness glass fiber, beautiful shape, resistants to natural factors and chemical material erosion, looks brand new even after long time use. All the steel shelves are processed by immersive hot galvanized zinc and comply with British BSEN ISO1461:1999 standard, reducing the oxidation mostly, prolong the service life.

 Easy Installation, Reasonable and Practical Usage
 Newin NSH series counter flow square type cooling towers can be paralleled for multi-units, flexible combination, widely used. The body structure is tidy, standardized, compact and strong, which is easy for installation. The design and manufacture are all on basis of practical uses, so it can meet customers' requirement better with high quality.

Components Instruction

Infill
Specially designed S shape PVC infill is vacuum formed of 0.3 thickness or more thicker PVC film with excellent chemical and high distortion resistance, big coefficient of heat transfer, small wind resistance, high ventilation performance. We have different materials like PVC, UPVC, and PP  to suit different water temperature. 
Drift Eliminator
The NSH series cooling tower used easy installed PVC material drift eliminator to prevent water from splashing out of the cooling tower.  
Air Inlet Louver
The air inlet louver is used of F.R.P parts which makes the long life of the whole cooling tower. For sewage water cooling tower, we will use different type of the air inlet louver to meet customers' requirements.
Distribution Nozzles
The distribution nozzles used high quality A.B.S / PP material, easy to installed on the water pipe and make sure the water splashed evenly on the infill.
Steel Structure 
Hop-dip galvanized steel framework to keep the cooling tower great performance and long lifespan, good anti-corrosion, guarantee the use of more than 15 years. Stainless steel hardware parts are also available for options if somewhere special condition needed.  
Sea Water Solution 
Newin cooling tower also provide special solution for sea water application which is suite for sea side industrial project will use sea water as cooling media. Please contact your related sales manager for more details.  

Square Counterflow FRP Cooling Tower for Power Plant 300 Ton

 
                  Item Nominal 
Flow 
(m3/h)
Water
  Pressure   
  (× 104  Pa)
Exhuast  Fan Weight  (T) Overall  Dimension               
          (mm)
DB  (A)
  Model Diameter 
(mm)
Motor   
(Kw× sets)
Net 
weight
Run.  
Weight
L W H
NST-80H/S 80 4 1500 3.0× 1 0.95 1.95 2000 2000 4000 60.0 
NST-100H/S 100 4 1800 4.0× 1 1.05 2.10  2250 2250 4000 60.0 
NST-125H/S 125 4 2100 4.0× 1 1.25 2.32  2500 2500 4000 61.0 
NST-150H/S 150 4 2100 5.5× 1 1.42 2.77  2750 2750 4000 62.0 
NST-175H/S 175 4.2 2400 5.5× 1 1.6 3.25  3000 3000 4200 62.0 
NST-200H/S 200 4.2 2400 7.5× 1 1.75 3.40  3250 3250 4200 62.5 
NST-250H/S 250 4.2 2400 7.5× 1 2.15 4.25  3500 3500 4200 63.0 
NST-300H/S 300 4.4 3200 11.0× 1 2.62 5.10  3750 3750 4400 63.5 
NST-350H/S 350 4.4 3200 11.0× 1 2.95 5.75  4000 4000 4400 64.0 
NST-400H/S 400 4.4 3400 15.0× 1 3.52 7.05  4500 4500 4400 64.5 
NST-160H/D 160 4 1500 3.0× 2 1.86 3.82  4000 2000 4000 62.0 
NST-200H/D 200 4 1800 4.0× 2 2.05 4.11  4500 2250 4000 62.0 
NST-250H/D 250 4 2100 4.0× 2 2.45 4.54  5000 2500 4000 63.0 
NST-300H/D 300 4 2100 5.5× 2 2.78 5.42  5500 2750 4000 64.5 
NST-350H/D 350 4.2 2400 5.5× 2 3.13 6.37  6000 3000 4200 64.5 
NST-400H/D 400 4.2 2400 7.5× 2 3.43 6.66  6500 3250 4200 65.0 
NST-500H/D 500 4.2 2400 7.5× 2 4.21 8.33  7000 3500 4200 65.0 
NST-600H/D 600 4.4 3200 11.0× 2 5.13 9.99  7500 3750 4400 66.5 
NST-700H/D 700 4.4 3200 11.0× 2 5.78 11.27  8000 4000 4400 66.0 
NST-800H/D 800 4.4 3400 15.0× 2 6.89 13.81  9000 4500 4400 66.5 
NST-240H/T 240 4 1500 3.0× 3 2.76 5.67 6000 2000 4000 63.0 
NST-300H/T 300 4 1800 4.0× 3 3.05 6.11  6750 2250 4000 63.0 
NST-375H/T 375 4 2100 4.0× 3 3.63 6.75  7500 2500 4000 64.0 
NST-450H/T 450 4 2100 5.5× 3 4.13 8.06  8250 2750 4000 65.5 
NST-525H/T 525 4.2 2400 5.5× 3 4.65 9.45  9000 3000 4200 65.5 
NST-600H/T 600 4.2 2400 7.5× 3 5.09 9.89  9750 3250 4200 66.5 
NST-750H/T 750 4.2 2400 7.5× 3 6.25 12.36  10500 3500 4200 66.5 
NST-900H/T 900 4.4 3200 11.0× 3 7.62 14.84  11250 3750 4400 67.0 
NST-1050H/T 1050 4.4 3200 11.0× 3 8.58 16.37  12000 4000 4400 67.5 
NST-1200H/T 1200 4.4 3400 15.0× 3 10.24 20.51  13500 4500 4400 68.0 
NST-320H/M 320 4 1500 3.0× 4 3.61 7.41  8000 2000 4000 64.5 
NST-400H/M 400 4 1800 4.0× 4 3.99 7.98  9000 2250 4000 64.5 
NST-500H/M 500 4 2100 4.0× 4 4.75 8.81  10000 2500 4000 65.5 
NST-600H/M 600 4 2100 5.5× 4 5.39 10.52  11000 2750 4000 67.0 
NST-700H/M 700 4.2 2400 5.5× 4 6.08 12.35  12000 3000 4200 67.0 
NST-800H/M 800 4.2 2400 7.5× 4 6.65 12.92  13000 3250 4200 68.0 
NST-1000H/M 1000 4.2 2400 7.5× 4 8.17 16.15  14000 3500 4200 68.0 
NST-1200H/M 1200 4.2 3200 11.0× 4 9.95 19.38  15000 3750 4400 68.5 
NST-1400H/M 1400 4.4 3200 11.0× 4 11.21 21.85  16000 4000 4400 69.0 
NST-1600H/M 1600 4.4 3400 15.0× 4 13.37 26.79  18000 4500 4400 69.5 
Square Counterflow FRP Cooling Tower for Power Plant 300 Ton
Jo.h Zhu
Sales Manager 
  

Shenzhen Newin Machinery c.,Ltd. 
Office Add: No.2H065, Trade Plaza No.5, China South City, Pinghu Street, Longgang Distact, Shenzhen, Guangdong Province, China. 
Factory Add: 1st Yangwu industrial Park, Houda Road, Dalingshan Town, Dongguan City, Guangdong Province, China 
Website: www.newincoolingtower.com
 

Percussion Drilling Rig

Percussion drilling is employed when auger or wash boring is not possible in very stiff soil or rock. It also can be used in most soil types.

Here the advancement of a hole is achieved by alternatively lifting and dropping a heavy cutting or hammering bit that is attached to a rope or cable that is lowered into an open hole or inside a temporary casing (casings are hollow cylindrical pipes used for borehole stability and to prevent the loss of drilling fluid through the boreholes).

Usually a tripod is used to support the cable. The stroke of bit varies according to the ground condition. The major disadvantage of this method is that it is not possible to get good-quality undisturbed samples. In very hard rock (and especially fractured hard rock), down-the-hole (DTH) drilling can be employed. In this case the hammer, applying repeated percussive pressure, is located just behind the drill bit inside the hole, unlike the open percussion drilling, where the hammer is on top of the drilling string.

The drilling string provides the necessary force and rotation to the hammer and bit, as well as compressed air or fluids to the hammer and for the flushing of cuttings.

This arrangement also allows for much deeper percussion drilling. However, the DTH drills are typically more expensive.

Percussion Drilling Rig,Cable Percussion Drilling,Percussion Drilling Equipment,Deep Foundation Engineering Percussion Rig

Henan YK Prospecting Machinery Co., Ltd , https://www.yyundergrounddrillingrig.com