VIB-15c vibration signal transmitter
Technical Parameters:

â—† External power supply: 220V AC or 24V DC
â—† Input
Signal: Receive a signal from a VS Series Vibration Speed ​​Sensor
Sensitivity: 20mV/mm/s±5%
Frequency response: 5 ~ 300Hz
◆ Range: 0 ~ 500μm (peak - peak) or 0 ~ 50.0mm / s (true RMS)
â—† LED indication: OK green, Alert, Danger red.
◆ Measurement error: ±1% of full scale
◆ Current output: 4~20mA active, output load ≤500Ω
◆ Alarm point setting: 0~100% full scale, accuracy ±1%
â—† Alarm reset mode: automatic or manual (site reset button, remote alarm reset terminal)
â—† Relay seal: epoxy resin, node capacity DC30V/5A or 220V/5A, single pole double throw
â—† Power-on delay: about 10 seconds
◆ Temperature range: -25°C~+65°C during operation, -40°C~+85°C during storage
â—† Relative humidity: up to 95%, no condensation

ZH1251-A60-B01 vibration (intensity) (speed) transmitter â—† external power supply: 220V AC or 11, TR203124V DC
â—† Input
Signal: Receive a signal from a VS Series Vibration Speed ​​Sensor
Sensitivity: 20mV/mm/s±5%
Frequency response: 5 ~ 300Hz
◆ Range: 0 ~ 500μm (peak - peak) or 0 ~ 50.0mm / s (true RMS)
â—† LED indication: OK green, Alert, Danger red.
◆ Measurement error: ±1% of full scale
◆ Current output: 4~20mA active, output load ≤500Ω
◆ Alarm point setting: 0~100% full scale, accuracy ±1%
â—† Alarm reset mode: automatic or manual (site reset button, remote alarm reset terminal)
â—† Relay seal: epoxy resin, node capacity DC30V/5A or 220V/5A, single pole double throw
â—† Power-on delay: about 10 seconds
◆ Temperature range: -25°C~+65°C during operation, -40°C~+85°C during storage
◆ Relative humidity: up to 95%, non-condensing Measurement range: Amplitude: 0 ~ 500μm (peak-to-peak);

Intensity: 0 ~ 50.0mm / s (true RMS);
- Frequency range: 5 to 3000 Hz;
- Measurement accuracy: 0.5, linear error ≤ ± 0.5%;
- Output signal: current output: 4 ~ 20mA, load resistance ≤ 850Ω;
- Use environment: -40 ° C ~ 65 ° C, relative humidity ≤ 95% (non-condensing);
- Power supply voltage: DC24V power consumption ≤ 1W;

VIB-15c vibration signal transmitter



When evaluating the operating state of a rotating machine, the relative axis vibration is the authoritative of all the signs of failure related to the condition of the machine. This is because it directly reflects the rapid radial movement of the rotor shaft relative to the bearing housing. It is a basic indicator. Many mechanical failures such as rotor imbalance, misalignment, bearing wear, shaft cracks, etc. can be detected.
Fault monitoring
Monitor the radial vibration of the rotating machine rotor, measure the shaft vibration, swing, eccentricity, etc., and monitor the vibration increase caused by the imbalance of the rotor, misalignment, loose parts.